Huashi Prefabricated Box Type Substation ( Data Masih Minim )
3 Dimension (3D) Wound Cores” are made from three identical single-core frames of trapezoidal silicon steel tape, wound into a compact triangular structure that eliminates air gaps. This innovative design ensures uniform flux flow, reduces total core weight, lowers no-load loss by 20-25%, and decreases excitation current by 50%, significantly minimizing reactive loss and improving the transformer’s power factor (Cos-phi).
- Description
- Additional information
- Reviews (0)
- GENERAL SPECIFICATIONS
- Store Policies
- Inquiries
Description
Hua-style Box Substation Transformer
- No need to add oil or refuel, eliminating the trouble of beauty changes
- The system does not need power outage and power generation is not affected
- Transformer power generation efficiency without exposure to sunlight**
- Oil quality is guaranteed to be pollution-free for 20 years
- Convenient and safe operation and maintenance, no problem in bad weather
- Comprehensive heat insulation protection and natural ventilation and heat dissipation
Outdoor Prefabricated Box Substation (EU)
Item | Unit | H.V electrical equipment | Transformer | L.V electrical equipment |
---|---|---|---|---|
Rated voltage | Kv | 10 | 10/0.4 | 0.4 |
Rated current | A | 630 | / | 100~2500 |
Rated frequency | Hz | 50 | 50 | 50 |
Rated capacity | kVA | / | 100~1250 | / |
Rated thermal stability current | kA | 20/45 | / | 30/15 |
Rated dynamic stability current (peak) | kA | 50 | / | 63 |
Rated closing short-circuit current (peak) | kA | 50 | / | 15~30 |
Rated breaking short circuit current | kA | 31.5(Fuse) | / | / |
Rated breaking load current | A | 630 | / | / |
1 min power frequency withstand voltage | kV | Between phases, to earth 42. to open contacts 48 | 35/28(5min) | 2.0/2.5 |
Lightning impulse withstand voltage | kV | Between phases, to earth 75. to open contacts 85 | 75 | / |
Shell protection class | IP33D, IP22D(Shell Of Transformer) | IP33D, IP22D(Shell Of Transformer) | IP33D, IP22D(Shell Of Transformer) | |
Noise level | dB | / | Oil transformer ≤55 Dry transformer ≤65 | |
Loops No. | 1~6 | 2 | 4~30 | |
Low voltage side max static var compensator | kvar | / | / | 300 |
Note
-
For sample purposes only, size depends on request.
Overall and mounting overall and mounting dimensions(mm) s(mm)
The YBM series of prefabricated substations includes Type 1 (see pic 1-1, 1-2) and Type 2 (see pic 1-3, 1-4). The overall and mounting dimensions (mm) can be found in pic 2 and pic 3.
YBM series prefabricated substation layout plan.
H-H.V chamber; T-Power transformer chamber; L-L.V chamber
Type 1 layout
Type 2 layout
Foundation drawing
Additional information
Weight | - kg |
---|---|
Dimensions | 5000 × 2850 × 1800 cm |
Capacity (kVa) | 10kVa, 12kVa |
Shell Material | Stainless Steel |
Be the first to review “Huashi Prefabricated Box Type Substation ( Data Masih Minim )” Cancel reply
Outdoor Prefabricated Box Substation (EU)
- Ambient air temperature: -10℃ ~+40℃
- Altitude: ≤1000m
- Solar radiation: ≤1000W/m²
- Ice cover: ≤20mm
- Wind speed: ≤35m/s
- Relative humidity: Daily average relative humidity ≤95%.Monthly average relative humidity ≤90%
- Daily average relative water vapour pressure ≤2.2kPa. Monthly average relative water vapour pressure ≤1.8kPa
- Earthquake intensity: ≤magnitude 8
- Applicable in the places without corrosive and flammable gas Note: Customized products are available
Outdoor Prefabricated Box Substation (EU)
- The product is connected together by high voltage power distribution equipment,transformer and low voltage power distribution device. And divided into three functional compartments, that is High voltage compartment, Power transformer compartment and Low voltage compartment, have completely HV, LV function.High voltage side of a power supply system, can be arranged in a ring network power supply, end user powersupply, dual power supply and other power supply, also can be provided with the high-voltage metering device to meet high voltage measurement. Transformer room can choose S9, SC and other series of low loss of oil immersed transformer or dry type transformer; low voltage chamber can be panel or cabinet mounted structure based on user requirement to form the power supply scheme required by user. These are power distribution,lighting distribution, Static Var Compensator, energy metering and energy measurement and other function, to meet different requirement of user. This make Power management convenient for users and improve the quality of power supply.
- The high voltage chamber with compact and reasonable structure,has a comprehensive antimis-operation interlock function. It can be equipped with a rail for power transformer when it is required by customer, it can make transformer in and out conveniently in power transformer compartment. Each room has the automatic lighting device, Meanwhile, all elements in high voltage and low voltage cabinet are reliable performance, convenient operation.
- Adopt natural ventilation and the forced ventilation in two ways.There is ventilation channel for power transformer compartment and High, Low voltage compartment. The exhaust fan is provided with a temperature control device, it can automatic startup and shutdown according to the setting temperature.This ensure the normal operation of transformer.
- The enclosure structure can prevent rain and dirt. The material adopt color steel plate and have anti-corrosion insulation function.
General Inquiries
There are no inquiries yet.
Reviews